EUSMUNC16 Joint materials by electro fusion processes
Overview
This Standard is about This Standard is about jointing materials by electro-fusion processes. Electro-fusion processes may be carried out in all weather conditions on parent materials with the same SDR rating, and polymer type.
Jointing materials by electro fusion includes providing weather protection, checking joint preparation, equipment and consumables, monitoring the jointing process, making electro-fusion joints to specification, shutting down equipment and dealing with waste.
This Standard is for anyone who carries out electro fusion jointing on utilities networks.
Performance criteria
You must be able to:
work in line with health, safety and environmental regulations, guidelines and procedures at all times
carry out and review site specific risk assessments in accordance with company procedures
select and wear required personal protective equipment in line with organisational procedures
check any circumstances where job instructions or organisational procedures appear incorrect with appropriate people
check that jointing and related equipment and consumables are as specified and fit for purpose
provide adequate weather protection in line with organisational procedures for the duration of jointing cycles
use lifting equipment when required in line with current regulations
report any damage or defects to tools, equipment or materials to appropriate people without delay
use appropriate electro-fusion jointing techniques to produce joints of the required quality
joint materials by electro-fusion processes in line with approved organisational procedures, practices and statutory and regulatory requirements
confirm compliance of completed joints with specified standards and specified dimensional accuracy
shut down equipment to a safe condition on completion of jointing activities
deal with excess and waste materials and temporary attachments without delay in line with organisational procedures
record and store jointing data and information in organisational information systems
resolve problems that are within your area of responsibility in line with organisational procedures
refer problems you cannot resolve to appropriate people using organisational procedures
Knowledge and understanding
You need to know and understand:
legislation, organisational procedures and codes of practice relating to health, safety and the environment including manual handling, use of equipment, hazardous materials, lifting equipment, work in excavations, risk assessments, accidents and personal protective equipment
the personal protective equipment (PPE) required for the work environment
the industry standards and organisational procedures relating to electro fusion jointing
the different types of pipe materials
how to interpret engineering specifications relevant to electro fusion processes
the different stages that take place during the jointing process and the importance of allowing each phase to complete
compatability between different materials in relation to standard dimension ration (SDR) rating and polymer type
the need for pipe support, restraint, alignment and the consequences of poor support, restraint and mis-alignment
organisational quality assurance procedures that can be used to recognise defects
the cause and effect of defects and contamination to pipes and fittings and how to avoid them
how to operate jointing equipment in line with organisational procedures
the importance of jointing equipment calibration and the consequences of poor maintenance
organisational reporting procedures including who to report to about damage and problems
organisational information and data storage systems
EUSMUNC16 Joint materials by electro fusion processes
Overview
This Standard is about This Standard is about jointing materials by electro-fusion processes. Electro-fusion processes may be carried out in all weather conditions on parent materials with the same SDR rating, and polymer type.
Jointing materials by electro fusion includes providing weather protection, checking joint preparation, equipment and consumables, monitoring the jointing process, making electro-fusion joints to specification, shutting down equipment and dealing with waste.
This Standard is for anyone who carries out electro fusion jointing on utilities networks.
Performance criteria
You must be able to:
Knowledge and understanding
You need to know and understand: